Code: C1038
Description: Engine connection failure
Master Board (PWB-A) to Control Board (PWB-C/C) connection failure • There is no acknowledge signal transmitted from the Master Board (PWB-A) to Control Board (PWB-C/C) for 1.5 sec. or more. • An error command signal is transmitted from the Control Board (PWB-C/C) to Master Board (PWB-A). • An error status signal is transmitted from the Master Board (PWB-A) to Control Board (PWB-C/C).
Master Board (PWB-A) to Control Board (PWB-C/C) connection failure • There is no acknowledge signal transmitted from the Master Board (PWB-A) to Control Board (PWB-C/C) for 1.5 sec. or more. • An error command signal is transmitted from the Control Board (PWB-C/C) to Master Board (PWB-A). • An error status signal is transmitted from the Master Board (PWB-A) to Control Board (PWB-C/C).
Remedy: 1 Turn OFF and ON the Power Switch. 2 Check the PWB-A connectors for proper connection and correct as necessary. 3 Check the PWB-C/C connectors for proper connection and correct as necessary. 4 Check for proper connection between PWB-A and PWB-C/C and correct as necessary. 5 Change PWB-A. 6 Change PWB-C/C.