Code: C0011
Description: Upper Drive Motor turning at abnormal timing
The Lock signal remains LOW for a continuous 1-sec. or more period 1sec. after the motor is deenergized.
The Lock signal remains LOW for a continuous 1-sec. or more period 1sec. after the motor is deenergized.
Remedy: 1 Upper Drive Motor operation: the voltage across PJ11A-9 on the Master Board and GND is DC5V after the malfunction has been reset. NO Change Master Board. 2 The voltage across PJ11A-8 on the Master Board and GND is DC5V after the malfunction has been reset. YES Change Master Board. NO Change motor.