Code: C004A
Description: Optical Section Cooling Fan Motor’s failure to turn
The Lock signal remains HIGH 1sec. after the motor is energized.
The Lock signal remains HIGH 1sec. after the motor is energized.
Remedy: 1 Optical Section Cooling Fan Motor operation: the voltage across PJ10A-2 on the Master Board and GND is DC24V (motor deenergized) and DC0V (motor energized) when the Start key is pressed. NO Change Master Board. 2 The voltage across PJ10A-3 on the Master Board and GND is DC24V (motor deenergized) and DC0V (motor energized) when the Start key is pressed. YES Change Master Board. NO Change motor.