Code: C004C
Description: Ventilation Fan Motor’s failure to turn
• The Lock signal remains HIGH for a continuous 12sec. or more period while the motor is energized (turning at high speed) when the Power Switch is turned ON. • The Lock signal remains HIGH for a continuous 3sec. or more period while the motor is energized (turning at high speed) during a copy cycle.
• The Lock signal remains HIGH for a continuous 12sec. or more period while the motor is energized (turning at high speed) when the Power Switch is turned ON. • The Lock signal remains HIGH for a continuous 3sec. or more period while the motor is energized (turning at high speed) during a copy cycle.
Remedy: 1 Ventilation Fan Motor operation: the voltage across PJ20A-1 on the Master Board and GND is DC24V during high-speed rotation and DC12V during low-speed rotation after the malfunction has been reset. NO Change Master Board. 2 The voltage across PJ20A-3 on the Master Board and GND is DC0V after the malfunction has been reset. YES Change Master Board. NO Change motor.