Mã lỗi C0070 — Konica-Minolta Di181

Code: C0070

Description: Toner Replenishing Motor’s failure to turn
• The Toner Bottle Home Position Sensor does not go from LOW to HIGH within 12 sec. after the motor has been energized. • The Toner Bottle Home Position Sensor does not go LOW within 12 sec. after the motor has been energized and the sensor has gone HIGH.
Remedy: 1 Toner Bottle turns when the Toner Bottle is turned a half turn and the Front Door is closed NO Correct drive coupling. 2 Toner Bottle Home Position Sensor operation: the voltage across PJ13A-9B on the Master Board and GND is DC0V (Toner Bottle at home position) and DC5V (Toner Bottle at a position other than home) when step 1 is performed. YES Change Master Board. NO Change sensor. 3 Toner Replenishing Motor operation: the voltage across PJ13A-9A on the Master Board and GND is DC0V (Toner Bottle at a stop) and DC24V (Toner Bottle turning) when step 1 is performed. YES Change motor. NO Change Master Board.