Code: C0071
Description: Toner Replenishing Motor turning at abnormal timing
The Toner Bottle Home Position Sensor is HIGH after the lapse of 2 sec. after the motor has been deenergized.
The Toner Bottle Home Position Sensor is HIGH after the lapse of 2 sec. after the motor has been deenergized.
Remedy: 1 Toner Bottle turns abnormally after the malfunction has been reset YES Change Master Board.