Mã lỗi C0500 — Konica-Minolta Di181

Code: C0500

Description: Warming-up failure
The surface temperature of the Upper Fusing Roller does not reach a given level even after the lapse of a given period of time during warming-up as detailed below: • From room temperature to 50°C: Within 20 sec. • From 50°C to 90°C: Within 20 sec. • From 90°C to 150°C: Within 20 sec. The copier fails to complete its warm-up cycle within 15 sec. after the temperature has reached 150°C.
Remedy: 1 Heater Lamp turns ON when the Power Switch is turned ON YES Correct Thermistor for mounting position and/or clean. NO Make checks from step 3 onward. 2 Thermistor operation: resistance across CN14- 2 and 3 on Fusing Unit side is infinite, as measured with CN14 (4P) disconnected. YES Change Thermistor. NO Change Master Board. 3 Fusing Thermoswitch and Heater Lamp operation: have continuity across CN5-1 and 2 on the Fusing Unit side with CN5 (2P) disconnected YES Change DC Power Supply 2. NO Change Fusing Thermoswitch and Heater Lamp. 4 The voltage across PJ7A-1 on the Master Board and GND is DC0V (Heater Lamp ON) and DC24V (Heater Lamp OFF) when the Power Switch is turned ON. YES Change Master Board. 5 The voltage across PJ4PU2-4 on DC Power Supply 2 and GND is DC0V (Heater Lamp ON) and DC24V (Heater Lamp OFF) when the Power Switch is turned ON. YES Change DC Power Supply 2. NO Plug in CN27 and CN14.

← Xem tất cả mã lỗi Konica-Minolta Di181

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie