Code: C0992
Description: Main Tray downward motion failure
Remedy: 1 Lower Limit Position Sensor operation: the voltage across PJ3A-6 on the Master Board and GND is DC5V (sensor unblocked) and DC0V (sensor blocked). YES Change Master Board. NO Change sensor, Cabinet Transport Board, and flat cable. 2 Main Tray Lower Position Sensor operation: the voltage across PJ3A-3 on the Master Board and GND is DC5V (sensor unblocked) and DC0V (sensor blocked). YES Change Master Board. NO Change sensor, Cabinet Transport Board, and flat cable.