Mã lỗi C0994 — Konica-Minolta Di181

Code: C0994

Description: Elevator Motor’s failure to turn
Remedy: 1 Elevator Motor turns when the Paper Descent key is pressed NO Correct drive coupling. 2 Elevator Motor operation: the voltage across PJ10A-1 (descent)/PJ10A-2 (ascent) on the Master Board and GND is DC0V (motor deenergized) and DC24V (motor energized) when the tray is slid in or the Paper Descent key is pressed. YES Change motor, Cabinet Transport Board, and flat cable. NO Change Master Board. 3 Elevator Motor Pulse Sensor operation: the voltage across PJ9A-5 on the Master Board and GND varies in the range between DC0V and DC5V while the Elevator Motor is energized. YES Change Master Board. NO Change pulse disk and gear. Change sensor.