Code: C0999 Description: Shifter return failure Remedy: 1 Shifter Return Position Sensor operation: the voltage across PJ3A-5 on the Master Board and GND is DC5V (sensor unblocked) and DC0V (sensor blocked). YES Change Master Board. NO Change sensor, Cabinet Transport Board, and flat cable.