Code: C0F02
Description: Original Size Detecting Board malfunction
Either the Original Size Detecting Board is faulty or an error occurs in communications with the Master Board. <During a copy cycle> A fixed-cycle pulse signal (Busy) remains HIGH or LOW for 0.5 sec. or more. <When the Power Switch is turned ON> A fixed-cycle pulse signal (Busy) remains HIGH or LOW for 5 sec. or more.
Either the Original Size Detecting Board is faulty or an error occurs in communications with the Master Board. <During a copy cycle> A fixed-cycle pulse signal (Busy) remains HIGH or LOW for 0.5 sec. or more. <When the Power Switch is turned ON> A fixed-cycle pulse signal (Busy) remains HIGH or LOW for 5 sec. or more.
Remedy: 1 J1 and J2 jumper connections on the Original Size Detecting Board are correct. NO Change jumper connector positions. 2 CN1 on the Original Size Detecting Board and PJ24A on the Master Board are connected. NO Connect. 3 The voltage across PJ24A-6 on the Master Board and GND varies in the range between DC0V and DC5V after the Power Switch has been turned ON. YES Change Master Board. NO Change Original Size Detecting Board.