Code: C0F30
Description: ATDC Sensor malfunction
The output from the ATDC Sensor remains less than 0.5V, or 4.5V or more, for a continuous 2-sec. period at any time 2 sec. after the Upper Drive Motor has started turning.
The output from the ATDC Sensor remains less than 0.5V, or 4.5V or more, for a continuous 2-sec. period at any time 2 sec. after the Upper Drive Motor has started turning.
Remedy: 1 PJ10 and CN39 connectors on the Master Board are properly connected NO Connect. 2 ATDC Sensor operation: the voltage across PJ10A-6 on the Master Board and GND varies in the range between DC0.5V and DC4.5V while the Upper Drive Motor is energized. YES Change Master Board. NO Change ATDC Sensor.