Code: C13F0
Description: SOS Sensor failure
After the lapse of a 5-sec. period after an SOS has been detected, no new SOS is detected.
After the lapse of a 5-sec. period after an SOS has been detected, no new SOS is detected.
Remedy: 1. Reset the malfunction. 2. If the malfunction is still detected, check the harness between, and PJ connections on, the PH Unit and Master Board. 3. If connections are okay, change the PH Unit and Master Board.