Mã lỗi C0F33 — Konica-Minolta Di183

Code: C0F33

Description: Improperly adjusted ATDC Sensor
• The adjustment of the ATDC control voltage is not completed within 1 sec. after sampling has started of the ATDC Sensor (UN1) as part of an operation of ATDC Sensor Automatic Adjustment. • The ATDC Sensor control voltage falls outside the range of 5.39 V to 8.15 V during an operation of ATDC Sensor Automatic Adjustment.
Remedy: 1 Developer is not even in the Developer Mixing Chamber. YES • Gently swing the IU in the horizontal direction to even out developer in the Developer Mixing Chamber. 2 ATDC Sensor (UN1) is dirty with foreign matter (such as paper dust) other than developer. YES • Clean ATDC Sensor (UN1). 3 Foreign matter (such as paper dust) is trapped in the Developer Mixing Chamber. YES • Remove foreign matter from the Developer Mixing Chamber. 4 The following voltages are supplied from the Master Board (copier: PWBA). <Check Procedure> Check voltage across a Master Board pin and GND when the Power Switch is turned ON. • DC5.39 V to 8.15 V across PJ7A-8 and GND • DC1.41 V to 4.98 V across PJ7A- 10 and GND YES • Change ATDC Sensor (UN1) and developer. NO • Change Master Board (copier: PWB-A).