Mã lỗi C0F32 — Konica-Minolta Di183f

Code: C0F32

Description: Faulty ATDC Sensor
• The measurement taken by the ATDC Sensor (UN1) at a time 2.5 sec. after the Main Motor (M1) has started turning is less than 3 % (greater than 4.98 V). • The measurement taken by the ATDC Sensor (UN1) at a time 2.5 sec. after the Main Motor (M1) has started turning is 19 % or more (1.41 V or less).
Remedy: 1 Developer is not even in the Developer Mixing Chamber. YES • Gently swing the IU in the horizontal direction to even out developer in the Developer Mixing Chamber. 2 ATDC Sensor (UN1) is dirty with foreign matter (such as paper dust) other than developer. YES • Clean ATDC Sensor (UN1). 3 Foreign matter (such as paper dust) is trapped in the Developer Mixing Chamber. YES • Remove foreign matter from the Developer Mixing Chamber. 4 The following voltages are supplied from the Master Board (copier: PWBA). <Check Procedure> Check voltage across a Master Board pin and GND when the Power Switch is turned ON. • DC5.39 V to 8.15 V across PJ7A-8 and GND • DC1.41 V to 4.98 V across PJ7A- 10 and GND YES • Change ATDC Sensor (UN1) and developer. NO • Change Master Board (copier: PWB-A).