Code: C0F33
Description: Improperly adjusted ATDC Sensor
• The adjustment of the ATDC control voltage is not completed within 1 sec. after sampling has started of the ATDC Sensor (UN1) as part of an operation of ATDC Sensor Automatic Adjustment. • The ATDC Sensor control voltage falls outside the range of 5.39 V to 8.15 V during an operation of ATDC Sensor Automatic Adjustment.
• The adjustment of the ATDC control voltage is not completed within 1 sec. after sampling has started of the ATDC Sensor (UN1) as part of an operation of ATDC Sensor Automatic Adjustment. • The ATDC Sensor control voltage falls outside the range of 5.39 V to 8.15 V during an operation of ATDC Sensor Automatic Adjustment.
Remedy: 1 Check to see if developer is available. 2 Check the ATDC Sensor connectors for proper connection and correct as necessary. 3 Change UN1. 4 Run ?gATDC Auto Adjust 5 Change PWB-A 6 Change PU1.