Mã lỗi C1300 — Konica-Minolta Di250

Code: C1300

Description: Polygon Motor malfunction
<Faulty start detection> • The Lock signal is not detected at any time during a given period of time 1 sec. after the Polygon Motor has been energized. <Faulty Lock signal detection> • No Lock signals are detected at any time during the 1-sec. period which starts 1 sec. after the first Lock. <Out-of-timing Lock detection> • The Lock signal is not detected for a continuous 0.5sec. period while the Polygon Motor is in the stabilized turning state. <Abnormal Lock detection> • The Lock signal remains ON for a continuous 5-sec. period while the Polygon Motor remains deenergized.
Remedy: 1. Reset the malfunction and turn OFF and ON the Power Switch. 2. Check the connection between PH Assy and Master Board. 3. Change PH Assy. Change Master Board.