Code: C0214
Description: Abnormal image transfer voltage
The image transfer voltage remains more than 100 V for a continuous 0.1-sec. period or more while the PC Drum remains stationary (except while an F2 operation is being run).
The image transfer voltage remains more than 100 V for a continuous 0.1-sec. period or more while the PC Drum remains stationary (except while an F2 operation is being run).
Remedy: 1 The voltage across CN11-1 on the side of Power Supply Unit and GND is DC24 V. The voltage across CN11-2 on the side of Power Supply Unit and GND is DC5 V. NO Change Power Supply Unit. 2 The voltage across CN17-12 on the side of Master Board and GND remains DC1.2 V or less while the malfunction code is being displayed. YES Change Master Board. 3 The voltage across CN17-15 on the side of Master Board and GND remains DC0.9 V or more while the malfunction code is being displayed. YES Change Master Board. NO Change High Voltage Unit.