Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C1300 — Konica-Minolta Di2510

Code: C1300

Description: Polygon Motor Failure
• The Polygon Motor Lock signal could not be detected within the set period of time after the Polygon Motor is energized. (Faulty start detection) • No First Lock signals are detected during the 1second period that starts 1 second after a First Lock signal. (Faulty lock signal detection) • The Polygon Motor Lock signal could not be detected after the set period of time has elapsed while the Polygon Motor is turning. (Out-of-timing lock detection) • The Polygon Motor Lock signal is set to ON for longer than the set period of time while the Polygon Motor remains stopped. (Abnormal lock detection)
Remedy: 1 Check the PH connector for proper connection, and correct as necessary. 2 Replace PH Unit. 3 Replace PWB-A.