Code: C0000
Description: Main Drive Motor M1 Overload, defective motor
The LOCK signal is not detected for 1 sec. or more after the motor has been energized. The LOCK signal is not detected for 0.5 sec. or more after the motor speed has built up to the constant range.
The LOCK signal is not detected for 1 sec. or more after the motor has been energized. The LOCK signal is not detected for 0.5 sec. or more after the motor speed has built up to the constant range.
Remedy: Check 1. Is DC24V being supplied from PWB-A to UN1? • Once the Power Switch has been turned ON, DC24V is being supplied across pins 7 and 6 (GND) of PJ7A on PWB-A. Check 2. Is an M1 drive control (ON/OFF) signal being output from PWB-A to UN1? • A voltage of approx. DC0V should be developing across pins 9 and 8 (GND) of PJ7A on PWB-A while M1 is being energized. (The voltage should be DC6V when M1 is deenergized.) Check 3. Is an M1 Lock (abnormal rotation check) signal is being output from UN1 to PWB-A? • A voltage of DC0V should be developing across pins 10 and 8 (GND) of PJ7A on PWB-A while M1 is being energized. (The voltage should be DC5V when M1 is deenergized.)