Code: C0010
Description: PC Drum Drive Motor Overload, defective motor
The LOCK signal is not detected for 0.6 sec. or more after the motor has been energized. The LOCK signal is not detected for 0.3 sec. or more after the motor speed has built up to the constant range.
The LOCK signal is not detected for 0.6 sec. or more after the motor has been energized. The LOCK signal is not detected for 0.3 sec. or more after the motor speed has built up to the constant range.
Remedy: Check 1. Is an M5 drive voltage of DC24V being supplied from PWB-A? • Once the Power Switch has been turned ON, DC24V is being supplied across pins 11 and 13 (GND) of PJ6A on PWB-A. Check 2. Is an M5 drive control (ON/OFF) signal being output from PWB-A? • A voltage of approx. DC0V should be developing across pins 12 and 13 (GND) of PJ6A on PWB-A while M5 is being energized. (The voltage should be DC6V when M5 is deenergized.) Check 3. Is an M5 Lock (abnormal rotation check) signal is being output from M5 to PWB-A? • A voltage of DC0V should be developing across pins 10 and 13 (GND) of PJ6A on PWB-A while M5 is being energized. (The voltage should be DC5V when M5 is deenergized.)