Code: C0040
Description: Ozone Ventilation Fan Motor Connector left disconnected, defective motor
The LOCK signal is not detected for 1.5 sec. or more after Power Switch S101 has been turned ON. The LOCK signal is not detected for 1.5 sec. or more after the motor speed has built up to the constant range.
The LOCK signal is not detected for 1.5 sec. or more after Power Switch S101 has been turned ON. The LOCK signal is not detected for 1.5 sec. or more after the motor speed has built up to the constant range.
Remedy: Check 1. Is the M4 drive voltage being supplied from PWB-A as follows? • The voltage across pins 1 and 3 (GND) of PJ7A on PWB-A should be as follows: When S101 is turned ON (in standby, turning at half speed) ... Approx. DC18V When Start Key is pressed (during a copy cycle, turning at full speed) ... Approx. DC23V Check 2. Is an M4 Lock (abnormal rotation check) signal being output from M4 to PWB-A? • A voltage of DC0V should be developing across pins 2 and 3 (GND) of PJ7A on PWB-A when M4 is energized.