Mã lỗi C004E — Konica-Minolta Di30

Code: C004E

Description: PU1 Cooling Fan Motor M101, PU2 Cooling Fan Motor M109 Connector left disconnected, defective motor
The LOCK signal is not detected for 5 sec. or more after Power Switch S101 has been turned ON. The LOCK signal is not detected for 5 sec. or more after the motor speed has built up to the constant range.
Remedy: <M101 Drive Check> Check 1. Is the M101 drive voltage being supplied from PWB-B as follows? • The voltage across pins 2 and 1 (M101 ON) of PJ5B on PWB-B should be as follows: When S101 is turned ON (in standby, turning at half speed) ... Approx. DC16V When Start Key is pressed (during a copy cycle, turning at full speed) ... Approx. DC22V Check 2. Is an M101 Lock (abnormal rotation check) signal being output from M101 to PWB-A? • A voltage of DC0V should be developing across pin 25 on PJ3A on PWB-A and GND when M101 is energized. <M109 Drive Check> Check 3. Is an M109 drive voltage of DC24V being supplied from PU-2 as follows? • Once the Power Switch has been turned ON, DC24V should be developing across pins 2 and 1 (GND) of PJ8PU2 on PU2. Check 4. Is an M109 Lock (abnormal rotation check) signal being output from M109 to PWB-A? • A voltage of DC0V should be developing across pin 26 on PJ3A on PWB-A and GND when M109 is energized.