Mã lỗi C0070 — Konica-Minolta Di30

Code: C0070

Description: Main Hopper Toner Replenishing Motor M7 Connector left disconnected, defective motor
Toner Bottle Position Detecting Sensor PC5 is not activated within 15 sec. after the motor has been energized.
Remedy: Check 1. Is power being supplied from PWB-A to PC5? • Once the Power Switch has been turned ON, DC5V should be developing across pins 5 and 7 (GND) of PJ8A. Check 2. Is PC5 fully operational? • The voltage across pins 6 and 7 (GND) of PJ8A should be DC0V when the Toner Bottle is turned to block PC5 (LOW). (The voltage should be DC5V when the Toner Bottle is at its home position.) Check 3. It is difficult to measure with a multimeter the drive condition between PWB-A and M7. • Square waves with a phase difference of 180° are output from pins 1 and 2 of PJ8A on PWB-A, thereby energizing M7. (It is therefore impossible to measure the voltage using a multimeter.)