Mã lỗi C0240 — Konica-Minolta Di30

Code: C0240

Description: Developing Bias Faulty bias, bias discharging/shorting
The SCD Malfunction signal is detected for 1 sec. or more when the Developing Bias output is turned ON.
Remedy: Check 1. Is power being supplied from PWB-A to HV1? • Once the Power Switch has been turned ON, there should be DC24V developing across pins 1 and 2 (GND) of PJ5A. Check 2. Is the Developing Bias ON signal being output from PWB-A to HV1? • When the developing bias output is ON, there should be DC0V developing across pins 8 and 2 (GND) of PJ5A on PWB-A. (When the output is OFF, there should be a voltage of approx. DC24V.) Check 3. Is the developing bias SCD signal being output from HV1 to PWB-A? • When bias leak occurs, there should be DC0V across pins 13 and 2 (GND) of PJ5A on PWB-A. (The voltage should be DC5V under normal conditions.)

← Xem tất cả mã lỗi Konica-Minolta Di30