Code: C0400
Description: Exposure Lamp LA2 Low intensity level, lamp out, lamp terminal/connector left disconnected
The intensity of the LA2 light is a level equivalent to 17/255 or less as detected by the CCD during the clamp level/dynamic range auto adjustment.
The intensity of the LA2 light is a level equivalent to 17/255 or less as detected by the CCD during the clamp level/dynamic range auto adjustment.
Remedy: Check 1. Is power (AC100V) being supplied to PU3? • Once the Power Switch has been turned ON, there should be AC100V developing across pins 1 and 5 of PJ3PU3 on PU3. Check 2. Is power (DC24V) being supplied from PU2 to PU3? • Once the Power Switch has been turned ON, there should be DC24V developing across pins 1 and 2 of PJ3PU3 on PU3? Check 3. Is the Exposure Lamp voltage being applied from PU3 to LA2? • When LA2 is ON, there should be DC0V across pins 4 and 3 (GND) of PJ3PU3 on PU3. • When LA2 is ON, an Exposure Lamp voltage of approx. DC60V should be output across pins 1 and 2 of PJ2PU3 on PU3.