Code: C0601
Description: Scanner Drive Motor Defective driver
No motor encoder pulses are output for 40 msec. after the motor has been energized.
No motor encoder pulses are output for 40 msec. after the motor has been energized.
Remedy: Check 1. Is power (DC24V/DC5V) being supplied to PWB-IE? • Once the Power Switch has been turned ON, there should be the following voltages across the respective pins of PJ2IE on PWB-IE: DC24V across pins 1 and 3 (GND) DC24V across pins 2 and 4 (GND) DC5V across pins 5 and 6 (GND) Check 2. Does PC6 detect the Scanner properly? • When the Scanner reaches PC6, it blocks PC6 (LOW) and DC0V should be developing across pins 12 and 11 (GND) of PJ3ID on PWB-ID. [The voltage becomes DC5V when PC6 is unblocked (HIGH).]