Code: C0651
Description: Faulty Scanner Home Position Sensor 2
When the Start key is pressed with a document loaded in the Document Feed Tray of the ADF, Scanner Home Position Sensor 2 is not blocked (L) even when the Scanner moves 463 mm to the left after the sensor has been unblocked (H).
When the Start key is pressed with a document loaded in the Document Feed Tray of the ADF, Scanner Home Position Sensor 2 is not blocked (L) even when the Scanner moves 463 mm to the left after the sensor has been unblocked (H).
Remedy: 1 Scanner Motor operation check: Select functions in the following order: Tech. Rep. Mode - Movement Check - Scanner; set +1000 in Relative Position?h and touch Set?h; the Scanner moves at this time. YES Check step 3 and onward. 2 The Scanner can be moved manually. YES Change Scanner Motor. Change BCR Board. Change MFB2 Board. Change Master Board. NO Correct drive coupling. 3 C0651 is displayed. YES Check step 7 and onward. 4 Scanner Home Position Sensor 1 operation check through I/O check YES Check to see if Scanner Home Position Sensor 1 is blocked as the Scanner is moved. If it is checked okay, change Master Board. 5 Scanner Home Position Sensor 1 operation check: the voltage across CN11BCR-1 on BCR Board and GND is DC0 V when the sensor is blocked and DC5 V when the sensor is unblocked. NO Change Scanner Home Position Sensor 1. 6 Scanner Home Position Sensor 1 operation check: the voltage across CN1BCR-26 on BCR Board and GND is DC0 V when the sensor is blocked and DC5 V when the sensor is unblocked. YES Change BCR Board. NO Change MFB2 Board. Change Master Board. 7 Scanner Home Position Sensor 2 operation check through I/O check YES Check to see if Scanner Home Position Sensor 2 is blocked as the Scanner is moved. If it is checked okay, change Master Board. 8 Scanner Home Position Sensor 2 operation check: the voltage across CN12BCR-1 on BCR Board and GND is DC0 V when the sensor is blocked and DC5 V when the sensor is unblocked. NO Change Scanner Home Position Sensor 2. 9 Scanner Home Position Sensor 2 operation check: the voltage across CN1BCR-27 on BCR Board and GND is DC0 V when the sensor is blocked and DC5 V when the sensor is unblocked. YES Change BCR Board. NO Change MFB2 Board. Change Master Board.