Mã lỗi C0510 — Konica-Minolta Di351

Code: C0510

Description: Abnormally low fusing temperature
• The fusing temperature remains 105 °C or less for a continuous 0.1-sec. period or more during the standby state or printing. • The fusing temperature remains a level lower than the following temperature for a continuous 2-min. period or more during the low-temperature standby state. 35-cpm copier: 105 °C 25-cpm copier: 80 °C 20-cpm copier (U.S.A. and Canada only): 80 °C
Remedy: 1 Fusing Roller Heater Lamp turns ON when the Side Cover is opened and closed. NO Check step 3 and onward. 2 The resistance of Fusing Roller Thermistor (across CN25-2 and 3 on the Fusing Unit end) is infinity. YES Change Fusing Roller Thermistor. NO Change Master Board. 3 There is continuity across CN3-1 and 2 on the Fusing Unit end. YES Check step 7. 4 Fusing Roller Heater Lamp is conducting. NO Change Fusing Roller Heater Lamp. 5 Fusing Roller Thermostat is conducting. NO Change Fusing Roller Thermostat. 6 Fusing Roller Heater Lamp Fuse is conducting. NO Change Fusing Roller Heater Lamp Fuse. 7 There is continuity across 1A and 1B, and across 2A and 2B, when Side Cover Interlock Switch 2 is actuated. YES Change Power Supply Unit. Change Master Board. NO Change Side Cover Interlock Switch 2.