Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C0651 — Konica-Minolta Di351

Code: C0651

Description: Faulty Scanner Home Position Sensor 2
When the Start key is pressed with a document loaded in the Document Feed Tray of the ADF, Scanner Home Position Sensor 2 is not blocked (L) even when the Scanner moves 463 mm to the left after the sensor has been unblocked (H).
Remedy: 1 Scanner Motor operation check: Select functions in the following order: Tech. Rep. Mode - Movement Check - Scanner; set +1000 in Relative Position?h and touch Set?h; the Scanner moves at this time. YES Check step 3 and onward. 2 The Scanner can be moved manually. YES Change Scanner Motor. Change BCR Board. Change MFB2 Board. Change Master Board. NO Correct drive coupling. 3 C0651 is displayed. YES Check step 7 and onward. 4 Scanner Home Position Sensor 1 operation check through I/O check YES Check to see if Scanner Home Position Sensor 1 is blocked as the Scanner is moved. If it is checked okay, change Master Board. 5 Scanner Home Position Sensor 1 operation check: the voltage across CN11BCR-1 on BCR Board and GND is DC0 V when the sensor is blocked and DC5 V when the sensor is unblocked. NO Change Scanner Home Position Sensor 1. 6 Scanner Home Position Sensor 1 operation check: the voltage across CN1BCR-26 on BCR Board and GND is DC0 V when the sensor is blocked and DC5 V when the sensor is unblocked. YES Change BCR Board. NO Change MFB2 Board. Change Master Board. 7 Scanner Home Position Sensor 2 operation check through I/O check YES Check to see if Scanner Home Position Sensor 2 is blocked as the Scanner is moved. If it is checked okay, change Master Board. 8 Scanner Home Position Sensor 2 operation check: the voltage across CN12BCR-1 on BCR Board and GND is DC0 V when the sensor is blocked and DC5 V when the sensor is unblocked. NO Change Scanner Home Position Sensor 2. 9 Scanner Home Position Sensor 2 operation check: the voltage across CN1BCR-27 on BCR Board and GND is DC0 V when the sensor is blocked and DC5 V when the sensor is unblocked. YES Change BCR Board. NO Change MFB2 Board. Change Master Board.

← Xem tất cả mã lỗi Konica-Minolta Di351

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie