Code: C0999
Description: Lift 2 ascent motion failure
Remedy: 1 Lift-Up Sensor 2 operation check through I/O check YES Check step 3 and onward. 2 Lift-Up Sensor 2 operation check: the voltage across CN4A-9 on LCC Control Board and GND is DC5 V when the sensor is blocked and DC0 V when the sensor is unblocked. YES Change LCC Control Board. Change Control Board. Change Master Board. NO Check actuator. Change Lift-Up Sensor 2. 3 LCC Lift-Up Motor operation check: LCC Lift- Up Motor turns after the cassette has been slid into the copier. YES Change Master Board. 4 LCC Lift-Up Motor operation check: the voltage across CN5A-2 on LCC Control Board and GND changes from DC0 V to DC24 V while step 3 is being performed. YES Change LCC Lift-Up Motor. NO Change LCC Control Board. Change Control Board. Change Master Board.