Mã lỗi C0072 — Konica-Minolta Di450

Code: C0072

Description: Main Hopper Toner Replenishing Motor’s failure to turn
• The Toner Bottle Home Position Sensor does not go HIGH within 5 sec. after the motor has started turning. • The Toner Bottle Home Position Sensor does not go LOW within 10 sec. after the motor has started turning and the sensor has gone HIGH. • The motor is stationary or the Toner Bottle Home Position Sensor is HIGH 2 sec. after the motor has stopped turning.
Remedy: 1 Toner Bottle turns when the Toner Bottle is turned a half turn and the Front Door is closed. NO Correct drive coupling. 2 I/O check for Toner Bottle Home Position Sensor operation: the voltage across PJ11A-5 on Master Board and GND is DC5V (Toner Bottle at home position) and DC0V (Toner Bottle at a position other than home) when step 1 is performed. YES Change Master Board. NO Check sensor for installation. Correct detecting plate. Change sensor. 3 Main Hopper Toner Replenishing Motor rotation: the voltage across PJ11A-1 on Master Board and GND is DC0V (Toner Bottle at a stop) and DC24V (Toner Bottle turning) when step 1 is performed. YES Change motor. NO Change Master Board.