Code: C0500
Description: Warming-up failure
The surface temperature of the Upper Fusing Roller does not reach a specified level even after the lapse of a predetermined period of time during warming-up as detailed below: • From room temperature to 90°C: Within 180 sec. • From 90°C to 140°C: Within 140 sec. • From 140°C to 170°C: Within 135 sec. The copier fails to complete its warm-up cycle within 135 sec. after the temperature has reached 170°C.
The surface temperature of the Upper Fusing Roller does not reach a specified level even after the lapse of a predetermined period of time during warming-up as detailed below: • From room temperature to 90°C: Within 180 sec. • From 90°C to 140°C: Within 140 sec. • From 140°C to 170°C: Within 135 sec. The copier fails to complete its warm-up cycle within 135 sec. after the temperature has reached 170°C.
Remedy: 1 Upper Fusing Roller Heater Lamp turns ON when the Power Switch is turned ON. YES Correct thermistor for mounting position and/or clean. 2 Lower Fusing Roller Heater Lamp turns ON when the malfunction is reset with the surface temperature of Lower Fusing Roller Heater Lamp is 140°C or less as indicated on Level History under the Tech. Rep. mode. NO Check step 7 and onward. 3 Upper and Lower Fusing Roller Thermistors are installed properly. NO Reinstall. 4 Upper and Lower Fusing Roller Thermistors are dirty. NO Clean. 5 Upper Fusing Roller Thermistor operation: the resistance across CN217-2 and 3 on the Fusing Unit end is infinity with CN217 (4P) disconnected. YES Change Upper Fusing Roller Thermistor. 6 Lower Fusing Roller Thermistor operation: the resistance across CN218-2 and 3 on the Fusing Unit end is infinity with CN218 (4P) disconnected. YES Change Lower Fusing Roller Thermistor. 7 Upper Fusing Roller Thermostat and Upper Fusing Roller Heater Lamp continuity: there is continuity across CN11-1 and 8 with CN11 (16P) disconnected. NO Change thermostat and heater lamp. 8 Lower Fusing Roller Heater Lamp continuity: there is continuity across CN11-9 and 16 with CN11 (16P) disconnected. NO Change heater lamp.