Code: C0510
Description: Abnormally low fusing temperature
• The surface temperature of the Upper Using Roller remains less than 120°C for a continuous period of 2 sec. or more after the copier has completed warming up. • The surface temperature of the Lower Using Roller remains 80°C or less for a continuous period of 2 sec. or more after the copier has completed warming up.
• The surface temperature of the Upper Using Roller remains less than 120°C for a continuous period of 2 sec. or more after the copier has completed warming up. • The surface temperature of the Lower Using Roller remains 80°C or less for a continuous period of 2 sec. or more after the copier has completed warming up.
Remedy: 1 Upper Fusing Roller Heater Lamp turns ON when the Power Switch is turned ON. YES Correct thermistor for mounting position and/or clean. 2 Lower Fusing Roller Heater Lamp turns ON when the malfunction is reset with the surface temperature of Lower Fusing Roller Heater Lamp is 140°C or less as indicated on Level History under the Tech. Rep. mode. NO Check step 7 and onward. 3 Upper and Lower Fusing Roller Thermistors are installed properly. NO Reinstall. 4 Upper and Lower Fusing Roller Thermistors are dirty. NO Clean. 5 Upper Fusing Roller Thermistor operation: the resistance across CN217-2 and 3 on the Fusing Unit end is infinity with CN217 (4P) disconnected. YES Change Upper Fusing Roller Thermistor. 6 Lower Fusing Roller Thermistor operation: the resistance across CN218-2 and 3 on the Fusing Unit end is infinity with CN218 (4P) disconnected. YES Change Lower Fusing Roller Thermistor. 7 Upper Fusing Roller Thermostat and Upper Fusing Roller Heater Lamp continuity: there is continuity across CN11-1 and 8 with CN11 (16P) disconnected. NO Change thermostat and heater lamp. 8 Lower Fusing Roller Heater Lamp continuity: there is continuity across CN11-9 and 16 with CN11 (16P) disconnected. NO Change heater lamp.