Mã lỗi C0510 — Konica-Minolta Di450

Code: C0510

Description: Abnormally low fusing temperature
• The surface temperature of the Upper Using Roller remains less than 120°C for a continuous period of 2 sec. or more after the copier has completed warming up. • The surface temperature of the Lower Using Roller remains 80°C or less for a continuous period of 2 sec. or more after the copier has completed warming up.
Remedy: 1 Upper Fusing Roller Heater Lamp turns ON when the Power Switch is turned ON. YES Correct thermistor for mounting position and/or clean. 2 Lower Fusing Roller Heater Lamp turns ON when the malfunction is reset with the surface temperature of Lower Fusing Roller Heater Lamp is 140°C or less as indicated on Level History under the Tech. Rep. mode. NO Check step 7 and onward. 3 Upper and Lower Fusing Roller Thermistors are installed properly. NO Reinstall. 4 Upper and Lower Fusing Roller Thermistors are dirty. NO Clean. 5 Upper Fusing Roller Thermistor operation: the resistance across CN217-2 and 3 on the Fusing Unit end is infinity with CN217 (4P) disconnected. YES Change Upper Fusing Roller Thermistor. 6 Lower Fusing Roller Thermistor operation: the resistance across CN218-2 and 3 on the Fusing Unit end is infinity with CN218 (4P) disconnected. YES Change Lower Fusing Roller Thermistor. 7 Upper Fusing Roller Thermostat and Upper Fusing Roller Heater Lamp continuity: there is continuity across CN11-1 and 8 with CN11 (16P) disconnected. NO Change thermostat and heater lamp. 8 Lower Fusing Roller Heater Lamp continuity: there is continuity across CN11-9 and 16 with CN11 (16P) disconnected. NO Change heater lamp.

← Xem tất cả mã lỗi Konica-Minolta Di450

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie