Code: C0924
Description: 1st Drawer Lift-Up Motor’s failure to turn
The 1st Drawer Paper Lift-Up Motor Pulse Sensor detects no edges of rotation detection pulses even after the lapse of 500 ms after the 1st Drawer Paper Lift-Up Motor has started turning.
The 1st Drawer Paper Lift-Up Motor Pulse Sensor detects no edges of rotation detection pulses even after the lapse of 500 ms after the 1st Drawer Paper Lift-Up Motor has started turning.
Remedy: 1 Lift-Up Motor turns when the 1st Drawer is slid out and then back in. NO Correct drive coupling. 2 1st Drawer Lift-Up Motor rotation: the voltage across PJ3A-13A on Master Board and GND is DC0V (motor deenergized) and DC24V (motor energized) after the 1st Drawer has been slid back in. YES Change motor. NO Change Master Board. 3 I/O check for 1st Drawer Lift-Up Motor Pulse Sensor operation: the voltage across PJ3A- 11A on Master Board and GND changes in the range between DC0V and DC5V while 1st Drawer Lift-Up Motor is turning. YES Change Master Board. NO Correct drive coupling. Change sensor. 4 I/O check for 1st Drawer Paper Lift-Up Sensor: the voltage across PJ4A-6B on Master Board and GND is DC0V (sensor unblocked) and DC5V (sensor blocked)