Code: C0042
Description: Fusing Unit Cooling Fan Motor’s failure to turn
The Lock signal remains HIGH for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has started turning at high speed.
The Lock signal remains HIGH for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has started turning at high speed.
Remedy: 1 Fusing Unit Cooling Fan Motor rotation: the voltage across PJ13C-1 on Power Supply Board and GND is DC24V (during high-speed rotation) and DC16V (during low-speed rotation) after the malfunction has been reset. NO Change Power Supply Board. 2 Fusing Unit Cooling Fan Motor rotation: the voltage across PJ13C-3 on Power Supply Board and GND is DC5V after the malfunction has been reset. YES Change Master Board. NO Check motor for installation. Change motor.