Code: C0045
Description: IR Cooling Fan Motor malfunction
The Lock signal remains HIGH for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has stopped turning.
The Lock signal remains HIGH for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has stopped turning.
Remedy: 1 IR Cooling Fan Motor rotation: the voltage across PJ4IC-4 on SCP Board and GND is DC24V (during high-speed rotation) and DC12V (during low-speed rotation) after the malfunction has been reset. NO Change SCP Board. 2 IR Cooling Fan Motor rotation: the voltage across PJ4IC-6 on SCP Board and GND is DC5V after the malfunction has been reset. YES Change SCP Board. NO Check motor for installation. Change motor.