Code: C004C
Description: Ventilation Fan Motor’s failure to turn
• The Lock signal remains HIGH for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has started turning. • The Lock signal remains LOW for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has stopped turning.
• The Lock signal remains HIGH for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has started turning. • The Lock signal remains LOW for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has stopped turning.
Remedy: 1 Ventilation Fan Motor rotation: the voltage across PJ9A-7B on Master Board and GND is DC24V when the Start key is pressed. NO Change Master Board. 2 Ventilation Fan Motor rotation: the voltage across PJ9A-5B on Master Board and GND is DC0V when the Start key is pressed. YES Change Master Board. NO Check motor for installation. Change motor.