Mã lỗi C0904 — Konica-Minolta Di470

Code: C0904

Description: 3rd Drawer Paper Lift-Up Motor’s failure to turn
Remedy: 1 Lift-Up Motor turns when the 3rd Drawer is slid out and then back in. NO Correct drive coupling. 2 3rd Drawer Paper Lift-Up Motor rotation: the voltage across PJ5A-3B on Control Board and GND is DC0V (motor deenergized) and DC24V (motor energized) after the 3rd Drawer has been slid back in. YES Change motor. NO Change Control Board. 3 I/O check for 3rd Drawer Lift-Up Motor Pulse Sensor operation: the voltage across PJ5A-9B on Control Board and GND changes in the range between DC0V and DC5V while 3rd Drawer Paper Lift-Up Motor is turning. YES Change Control Board. NO Correct drive coupling. Change sensor. 4 I/O check for 3rd Drawer Paper Lift-Up Sensor: the voltage across PJ8A-2 on Control Board and GND is DC0V (sensor unblocked) and DC5V (sensor blocked). YES Change Control Board. NO Change sensor.