Code: C0010
Description: PC Drum Drive Motor’s failure to turn
• The Lock signal remains HIGH for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has started turning. • The Lock signal remains LOW for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has stopped turning.
• The Lock signal remains HIGH for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has started turning. • The Lock signal remains LOW for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has stopped turning.
Remedy: 1 PC Drum Drive Motor turns when the Start key is pressed. NO Correct drive coupling. 2 PC Drum Drive Motor rotation: the voltage across PJ7A-3A on Master Board and GND is DC5V (motor deenergized) and DC0V (motor energized) when the Start key is pressed. NO Change Master Board. 3 PC Drum Drive Motor rotation: the voltage across PJ7A-4A on Master Board and GND is DC5V (motor deenergized) and DC0V (motor energized) when the Start key is pressed. YES Change Master Board. NO Change motor.