Code: C0400
Description: Exposure Lamp’s failure to turn ON
• During a light intensity adjustment sequence, the CCD read data does not exceed the specified level when the peak of the intensity of light is detected within 1 min. after the Exposure Lamp has turned ON. • Under normal conditions, the CCD read data does not exceed the specified level 450 ms after the Exposure Lamp has turned ON.
• During a light intensity adjustment sequence, the CCD read data does not exceed the specified level when the peak of the intensity of light is detected within 1 min. after the Exposure Lamp has turned ON. • Under normal conditions, the CCD read data does not exceed the specified level 450 ms after the Exposure Lamp has turned ON.
Remedy: 1 Exposure Lamp has discolored. YES Change Exposure Lamp. 2 NG is displayed when “Scanning Check” of Function (IR) is run. YES Check the optical path. Change Image Processing Board or CCD Board. 3 Power Supply Board operation: the voltage across PJ9C-4 on Power Supply Board and GND is DC24V after the malfunction has been reset. YES Check and change, as necessary, flat cable. Change Inverter Board or Image Processing Board. NO Change Power Supply Board.