Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C0420 — Konica-Minolta Di550

Code: C0420

Description: Exposure Lamp turning ON at abnormal timing
During a light intensity adjustment sequence, the adjusted value for the intensity of light remains at the lower limit and the CCD output level is at the saturation level even after the lapse of 2 sec. after the Exposure Lamp has turned ON.
Remedy: 1 Exposure Lamp has discolored. YES Change Exposure Lamp. 2 NG is displayed when “Scanning Check” of Function (IR) is run. YES Check the optical path. Change Image Processing Board or CCD Board. 3 Power Supply Board operation: the voltage across PJ9C-4 on Power Supply Board and GND is DC24V after the malfunction has been reset. YES Check and change, as necessary, flat cable. Change Inverter Board or Image Processing Board. NO Change Power Supply Board.