Code: C0602
Description: Cable unwound
A Scanner drive command is issued when the Scanner is at its home position and the Scanner Reference Position Sensor remains blocked even after the lapse of a given period of time (after the Scanner has been driven to move a given distance thereafter).
A Scanner drive command is issued when the Scanner is at its home position and the Scanner Reference Position Sensor remains blocked even after the lapse of a given period of time (after the Scanner has been driven to move a given distance thereafter).
Remedy: 1 Scanner moves as moved manually. NO Correct drive coupling. Rewind cables. 2 Connector on SCP Board is connected properly: PJ3IC on PWB-IC. NO Connect. 3 Scanner Motor turns when the Start key is pressed. NO Correct drive coupling. Change motor or SCP Board. 4 Connector on Image Processing Board is connected properly: PJ306B on PWB-B. NO Connect. 5 I/O check for Scanner Reference Position Sensor YES Change Image Processing Board. NO Correct actuator. Change sensor.