Code: C0000
Description: Fusing Motor’s failure to turn
• The Lock signal remains HIGH for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has started turning. • The Lock signal remains LOW for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has stopped turning.
• The Lock signal remains HIGH for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has started turning. • The Lock signal remains LOW for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has stopped turning.
Remedy: 1 Fusing Motor turns when the Start key is pressed. NO Correct drive coupling. 2 Fusing Motor rotation: the voltage across PJ7A-1A on Master Board and GND is DC5V (motor deenergized) and DC0V (motor energized) when the Start key is pressed. NO Change Master Board. 3 Fusing Motor rotation: the voltage across PJ7A-2A on Master Board and GND is DC5V (motor deenergized) and DC0V (motor energized) when the Start key is pressed. YES Change Master Board. NO Change motor.