Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C0994 — Konica-Minolta Di552

Code: C0994

Description: Main Tray Elevator Motor’s failure to turn
Remedy: 1 Elevator Motor turns when the Paper Descent key is pressed. NO Correct drive coupling. 2 Elevator Motor rotation: the voltage across PJ7A-6B (ascent)/PJ7A-7B (descent) on Control Board and GND is DC0V (motor deenergized) and DC24V (motor energized) when the drawer is slid in or the Paper Descent key is pressed. YES Change motor or Cabinet Transport Board. Change flat cable. NO Change Control Board. 3 I/O check for Elevator Motor Pulse Sensor operation: the voltage across PJ7A-5A on Control Board and GND changes in the range between DC0V and DC5V while the Elevator Motor is turning. YES Change Control Board. NO Change gear or sensor.