Code: SVC E0
Description: Developer motor 1 over current error
Causes: An over-current signal is detected due to an abnormal load on developer motor 1
Remedy: 1. Replace black and magenta toner cartridge. 1 Are there any unusual noises heard around developer motor or developer drive assembly before error posts? Replace toner cartridge (customer ordered supply). Go to step 2. Go to step 4.
2 Does noise go away? Problem solved. Replace developer drive assembly. . Go to step 3.
3 Does noise go away? Problem solved. Go to step 4.
4 Turn printer off and remove right cover. Is cable properly connected to developer drive assembly motor? Go to step 5. Properly connect cable. Retest printer. If error clears, problem solved, otherwise go to step 5.
5 If waste toner bottle is removed, reinsert it. Ensure rear cover assembly is shut. Override top and front cover interlock switches. For location, . Reconnect operator panel. Turn printer on. Allow printer to run until error posts. Disconnect connector from each developer motor and check for the following on each disconnected cable connector: Pin 2 to ground—24VDC Pin 5 to ground—24VDC Are voltages present? Replace developer drive assemblyr. See “Developer drive assembly removal”. Go to step 8 Go to step 6.
6 Remove engine controller board board shield. See “Engine controller board removal” for steps to remove engine controller board shield. Disconnect MCN5 from engine controller board. Check for continuity and shorted pins on cable that connects MCN5 to developer motors. Is cable okay? Go to step 7. Replace cable. Retest printer. If error clears, problem solved, otherwise go to step 7.
7 Disconnect cable from engine controller board POCN. Check the following on disconnected cable connector: Pin 21 to pin 22—24VDC Pin 13 to pin 14—5VDC Are voltages present? Replace engine controller board. See “Engine controller board removal”. Go step 8. Replace cable that connects ACN1 on LVPS to POCN on engine controller board. Remove RIP board cage to gain access to cable. See “System board cage removal”. Go to step 8.
8 Reassemble and retest printer. Does error clear? Problem solved. Contact next level of maintenance.
2 Does noise go away? Problem solved. Replace developer drive assembly. . Go to step 3.
3 Does noise go away? Problem solved. Go to step 4.
4 Turn printer off and remove right cover. Is cable properly connected to developer drive assembly motor? Go to step 5. Properly connect cable. Retest printer. If error clears, problem solved, otherwise go to step 5.
5 If waste toner bottle is removed, reinsert it. Ensure rear cover assembly is shut. Override top and front cover interlock switches. For location, . Reconnect operator panel. Turn printer on. Allow printer to run until error posts. Disconnect connector from each developer motor and check for the following on each disconnected cable connector: Pin 2 to ground—24VDC Pin 5 to ground—24VDC Are voltages present? Replace developer drive assemblyr. See “Developer drive assembly removal”. Go to step 8 Go to step 6.
6 Remove engine controller board board shield. See “Engine controller board removal” for steps to remove engine controller board shield. Disconnect MCN5 from engine controller board. Check for continuity and shorted pins on cable that connects MCN5 to developer motors. Is cable okay? Go to step 7. Replace cable. Retest printer. If error clears, problem solved, otherwise go to step 7.
7 Disconnect cable from engine controller board POCN. Check the following on disconnected cable connector: Pin 21 to pin 22—24VDC Pin 13 to pin 14—5VDC Are voltages present? Replace engine controller board. See “Engine controller board removal”. Go step 8. Replace cable that connects ACN1 on LVPS to POCN on engine controller board. Remove RIP board cage to gain access to cable. See “System board cage removal”. Go to step 8.
8 Reassemble and retest printer. Does error clear? Problem solved. Contact next level of maintenance.