Mã lỗi SVC F0 — Lexmark C500N

Code: SVC F0

Description: Power supply fan error
Causes: Improper fan motor rotation, improper fan motor cable connection or a shorted or cut cable
Remedy: 1 Turn printer off and remove engine controller board board shield. See “Engine controller board removal” for steps to remove engine controller board shield. Is cable properly connected to engine controller board connector MCN10? Go to step 2. Properly connect cable.
2 Ensure rear cover assembly cover is shut. Override top and front cover interlock switches. For location, see “Interlock switch locations”. Reconnect operator panel. Turn printer on and check for 24VDC between engine controller board MCN10 pin 1 and power ground (you can touch negative lead of voltmeter to metal frame to obtain ground.) Is voltage present and correct? Replace power supply fan assembly. See “Power supply fan removal”. Retest printer. If error clears, problem solved, otherwise go to step 3. Go to step 3.
3 Turn printer off and disconnect cable from engine controller board MCN10 and power supply fan. Check cable for continuity and pin shorts. Is cable okay? Replace engine controller board. See “Engine controller board removal”. Replace cable.

← Xem tất cả mã lỗi Lexmark C500N