Code: SVC F5
Description: HV power supply (HVPS) error
Causes: Output (BRV) of HVPS is shorted, and or HVPS cable connector is improperly connected.
Remedy: 1 Remove photodeveloper cartridge and ensure charging unit on bottom of photodeveloper cartridge is not damaged. Is charging unit damaged? Replace photodeveloper cartridge. See “Photodeveloper cartridge removal”. Note: Photo-developer cartridge is a customer ordered part. Go to step 2.
2 Check charging unit high voltage contacts in printer. Are they clean? Go to step 3. Clean contacts. If problem persists, go to step 3.
3 Replace photodeveloper cartridge. See “Photodeveloper cartridge removal”. Has error cleared? Note: Photo-developer cartridge is a customer ordered part. Problem solved. Go to step 4.
4 Check cable for continuity between engine controller board connector HVCN and HVPS BCN1 connector and for shorted pins. Is cable okay? Go to step 5. Replace cable.
5 Replace HVPS. See “High voltage power supply (HVPS) removal”. Has error cleared? Problem solved. Go to step 6.
6 Replace engine controller board. See “Engine controller board removal”. Has error cleared? Problem solved. Contact higher level support.
2 Check charging unit high voltage contacts in printer. Are they clean? Go to step 3. Clean contacts. If problem persists, go to step 3.
3 Replace photodeveloper cartridge. See “Photodeveloper cartridge removal”. Has error cleared? Note: Photo-developer cartridge is a customer ordered part. Problem solved. Go to step 4.
4 Check cable for continuity between engine controller board connector HVCN and HVPS BCN1 connector and for shorted pins. Is cable okay? Go to step 5. Replace cable.
5 Replace HVPS. See “High voltage power supply (HVPS) removal”. Has error cleared? Problem solved. Go to step 6.
6 Replace engine controller board. See “Engine controller board removal”. Has error cleared? Problem solved. Contact higher level support.