Code: 995
Description: Charger HV unit error
Indicates a problem with HVPS charging voltage supplied to the OPC (photodeveloper cartridge) charging unit.
Indicates a problem with HVPS charging voltage supplied to the OPC (photodeveloper cartridge) charging unit.
Remedy: 1 Remove photodeveloper cartridge and ensure charging unit on bottom of photodeveloper cartridge is not damaged. Is charging unit damaged? Replace photodeveloper cartridge. Note: Photodeveloper cartridge is a customer ordered part. Go to step 2.
2 Check charging unit high voltage contacts in printer. Are they clean? Go to step 3. Clean contacts. If problem persists, go to step 3.
3 Replace photodeveloper cartridge. Has error cleared? Note: Photodeveloper cartridge is a customer ordered part. Problem solved. Go to step 4.
4 Check cable for continuity between engine controller board connector HVCN and HVPS CN1 connector and for shorted pins. Is cable okay? Go to step 5. Replace cable.
5 Replace HVPS. Has error cleared? Problem solved. Go to step 6.
6 Replace engine controller board. Has error cleared? Problem solved. Replace I/O board.
2 Check charging unit high voltage contacts in printer. Are they clean? Go to step 3. Clean contacts. If problem persists, go to step 3.
3 Replace photodeveloper cartridge. Has error cleared? Note: Photodeveloper cartridge is a customer ordered part. Problem solved. Go to step 4.
4 Check cable for continuity between engine controller board connector HVCN and HVPS CN1 connector and for shorted pins. Is cable okay? Go to step 5. Replace cable.
5 Replace HVPS. Has error cleared? Problem solved. Go to step 6.
6 Replace engine controller board. Has error cleared? Problem solved. Replace I/O board.