Code: 6801
Description: The side thermistor of the fuser unit or internal temperature sensor detected a temperature higher than the specified value.
Remedy: • Lower the room temperature. • Keep the machine away from heating appliances.
1 Connection failure of the internal temperature sensor harness Reconnect the internal temperature sensor harness. 2 Internal temperature sensor failure Replace the main frame L ASSY. 3 Fuser unit side thermistor failure Replace the fuser unit. 4 Main PCB failure Replace the main PCB ASSY.
1 Connection failure of the internal temperature sensor harness Reconnect the internal temperature sensor harness. 2 Internal temperature sensor failure Replace the main frame L ASSY. 3 Fuser unit side thermistor failure Replace the fuser unit. 4 Main PCB failure Replace the main PCB ASSY.